A AegiFlow
MEDIUMCVSS 4.4

CVE-2026-102703

CVE-2026-102703 updated by NVD

Modified
2026-11-06
Sources
nvd

Summary

[This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] A common access pattern is a batch of Grant Copy operations acting on adjacent address ranges in the same source or destination page. For performance reasons, Xen caches details internally to reuse already validated data. The conditions on when to re-validate the internal data were not correct in some cases: - Frame numbers and grant references could wrongly be mixed up. This is CVE-2026-102703. - Copying by frame number (rather than grant reference) is permitted only when operating on the caller's own memory. The check to enforce this restriction was misplaced. This is CVE-2026-102704.

References

Includes data from the National Vulnerability Database (NIST). NVD data is in the public domain; this page is not endorsed by NIST.

CVE® is a registered trademark of The MITRE Corporation. CVE content reproduced under the CVE Terms of Use; copyright designation © MITRE.