A AegiFlow
MEDIUMCVSS 6.9

CVE-2026-33774

CVE-2026-33774 updated by NVD

Modified
2026-10-28
Sources
nvd

Summary

An Improper Check for Unusual or Exceptional Conditions vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on MX Series allows an unauthenticated, network-based attacker to bypass the configured firewall filter and access the control-plane of the device. On MX platforms with MPC10, MPC11, LC4800 or LC9600 line cards, and MX304, firewall filters applied on a loopback interface lo0.n (where n is a non-0 number) don't get executed when lo0.n is in the global VRF / default routing-instance. An affected configuration would be: user@host# show configuration interfaces lo0 | display set set interfaces lo0 unit 1 family inet filter input where a firewall filter is applied to a non-0 loopback interface, but that loopback interface is not referred to in any routing-instance (RI) configuration, which implies that it's used in the default RI. The issue can be observed with the CLI command: user@device> show firewall counter filter not showing any matches. This issue affects Junos OS on MX Series: * all versions before 23.2R2-S6, * 23.4 versions before 23.4R2-S7, * 24.2 versions before 24.2R2, * 24.4 versions before 24.4R2.

References

Includes data from the National Vulnerability Database (NIST). NVD data is in the public domain; this page is not endorsed by NIST.

CVE® is a registered trademark of The MITRE Corporation. CVE content reproduced under the CVE Terms of Use; copyright designation © MITRE.