CVE-2026-80711
CVE-2026-80711 updated by NVD
Summary
In the Linux kernel, the following vulnerability has been resolved: power: supply: max17040: handle missing status supplier MAX17040 does not report charger state itself, so the driver forwards POWER_SUPPLY_PROP_STATUS to a supplier power supply. If no supplier is registered, power_supply_get_property_from_supplier() returns -ENODEV and leaves the output value untouched. max17040_get_property() currently ignores that error and returns success, so userspace can read an uninitialized status value from the battery power supply. This happens on systems that use the fuel gauge without a charger supplier relationship in firmware. Return POWER_SUPPLY_STATUS_UNKNOWN when no supplier provides STATUS, and propagate other supplier lookup errors.
References
Includes data from the National Vulnerability Database (NIST). NVD data is in the public domain; this page is not endorsed by NIST.
CVE® is a registered trademark of The MITRE Corporation. CVE content reproduced under the CVE Terms of Use; copyright designation © MITRE.